Environmental and Reliability Testing

  • - Electric refrigerator
  • commercial refrige rators
  • freezer
  • showcase
  • vending machine
  • kimchi fridge
  • Refrigerant compressors
  • air compressor
Balanced ambient room type calorimeter
  • KS C 9306 , ISO 5151
  • Cooling Capacity : (1~10) KW
  • Heating Capacity : (1~10) KW
Environmental chamber
  • KS C IEC 62552, KS C 9321 KS P 6108, ISO 5155, ISO 7371, ISO 8187
  • Operating Temperature : (-20~80) ℃
  • Relative Humidity : (20~85) % R.H
Compressor calorimeter
  • Air-Compressor Performance Testing

    - KS B 6351, ISO 1217
    - Compression Capacity : (8~50) KW

  • Refrigerant Compressor Performance Testing

    - KS B 6365 , KS B 6226
    - Type Gas Cycle

Reliability test chamber
  • KS C OEC 62552, KS C 9321, ISO 5155, ISO 7371, ISO 8187
  • Operating temperature : (-30~80) ℃
  • Relative Humidity : (20~85) % R.H